As an interlock function when using a stirring tank, we propose an option that can control the emergency stop when the tank lid is opened and closed.
Product Categories
Browse By Application
Browse By Industry
As an interlock function when using a stirring tank, we propose an option that can control the emergency stop when the tank lid is opened and closed.
1) For electric motor stirrer (safety cover, contact switch interlocking type)
Contact Switch |
|
Safety Control Box (Top) |
Product Description
This function forcibly releases the internal pressure of the tank when the lid of the pressurized tank is opened, and forcibly stops the stirrer.
The stirrer is forcibly stopped to prevent unexpected accidents caused by the stirrer being exposed while still running.
In addition, when opening or closing a ferrule clamp type tank, if you try to remove the clamp while pressure is still applied, this function works in conjunction with the “safety cover” which forcibly exhausts air from the valve. This prevents accidents when opening or closing the lid of the pressurized tank.
Features
Recommended for the following cases
Customers considering safety measures to prevent the lid from flying off when using a ferrule clamp type pressure tank, and safety measures for electric motor stirrer
*A safety cover and a receiving base for the contact switch will be added to the tank lid.
2) For air motor stirrer (mechanical operation switch type)
Product Description
When the tank lid is opened, the mechanical operation switch is activated, cutting off the air supply that powers the air motor-type stirrer, forcibly stopping the stirrer.
Features
Recommended for the following cases
*A stand for the mechanical operation switch will be added to the tank body.
3) For electric motor agitators (limit switch type)
Product Description
When the tank lid is opened, the limit switch is activated and cuts off the power supply to the electric motor-driven stirrer, forcibly stopping the stirrer.
Features
Recommended in the following cases:
*A stand for the mechanical operation switch will be added to the tank body.